In short. Average ac power is P = V rms I rms cos(phi), with power factor cos(phi) = R/Z; a pure inductor or capacitor absorbs no average power, so the current component I sin(phi) is wattless. A generator gives peak emf N B A w, and an ideal transformer changes voltage by the turns ratio.

  • Average power P = V rms I rms cos(phi) = I rms² R; only the resistance dissipates energy, and the power factor is R/Z.
  • A pure L or C has phi = 90 degrees, zero power factor and zero average power; the current in it is wattless.
  • An ac generator rotating a coil of N turns and area A in a field B at w gives e = N B A w sin(w t), with peak emf N B A w.
  • An ideal transformer obeys Vs/Vp = Ns/Np = Ip/Is, with Vp Ip = Vs Is; step-up raises voltage and lowers current.
  • Real transformers lose power by copper loss, eddy currents, hysteresis and flux leakage, and high-voltage transmission cuts line loss I² R.

Syllabus line: Electromagnetic Induction and Alternating Currents Electromagnetic induction: Faraday's law, induced emf and current, Lenz's law, eddy currents, self and mutual inductance. Alternating currents, peak and RMS value of alternating current/voltage, reactance and impedance, LCR series circuit, resonance, power in AC circuits, wattless current, AC generator and transformer. (NTA JEE (Main) 2026 syllabus, Physics, Unit 14 (https://jeemain.nta.nic.in/document/syllabus-2026/))

Before you start

Prerequisites

Related topics

The concept step by step

  1. Instantaneous and average power

    With v = V0 sin(w t) and i = I0 sin(w t - phi), the instantaneous power p = v i keeps changing and is sometimes negative, which means energy returning to the source from the inductor or capacitor. Averaging over a cycle gives P = (1/2) V0 I0 cos(phi) = V rms I rms cos(phi). For a pure resistor phi = 0 and P = V rms I rms. For a pure inductor or capacitor phi = 90 degrees, cos(phi) = 0, and the average power is zero although a current flows.

  2. Power factor

    The factor cos(phi) is the power factor. In a series circuit cos(phi) = R/Z, so P = V rms I rms R/Z = I rms² R: all the average power is dissipated in the resistance. The power factor lies between 0 and 1 and is 1 at resonance. The product V rms I rms is the apparent power in volt-ampere, and P = apparent power x power factor. A low power factor means a large current is needed for a given useful power, which means greater line loss, so supply companies prefer a power factor near 1.

  3. Wattless current

    Split the current into two components relative to the voltage: I cos(phi) in phase with the voltage, which does the work, and I sin(phi) at 90 degrees to the voltage, which does no net work over a cycle. The second is the wattless (reactive) current. For a pure inductor or capacitor the whole current is wattless. Its value is I rms sin(phi) = I rms (X/Z), and the total current is the vector (phasor) sum of the active component I cos(phi) and the wattless component I sin(phi), so I² = (I cos(phi))² + (I sin(phi))². It still heats the supply wires, as heat depends on the total current.

  4. The AC generator

    A coil of N turns and area A rotating at angular speed w in a uniform field B has flux N B A cos(w t) when the angle is measured from the position with the plane perpendicular to the field. By Faraday law the emf is e = N B A w sin(w t), a sinusoid of peak E0 = N B A w and frequency f = w/(2 pi). The emf is largest when the plane of the coil is parallel to the field (the flux is zero but changing fastest) and zero when the plane is perpendicular to the field. The mechanical work needed to turn the coil is what the electrical energy comes from, which is Lenz law again, since the current produces a retarding torque.

  5. The transformer

    A transformer has a primary and a secondary coil on a common soft-iron core. The alternating current in the primary sets up a changing flux that links both coils. For an ideal transformer the same flux passes through every turn, so the emf per turn is the same: Vs/Vp = Ns/Np. With no loss the power is unchanged, Vp Ip = Vs Is, so Is/Ip = Np/Ns. A step-up transformer (Ns more than Np) raises the voltage and lowers the current; a step-down transformer does the reverse. A transformer works only with ac, since dc gives no changing flux and so no induced emf.

  6. Losses and transmission

    A real transformer has an efficiency below 100 percent: copper loss in the winding resistance, eddy currents in the core (cut by laminations), hysteresis loss (cut by soft iron) and flux leakage (reduced by winding the coils on top of each other). Efficiency is output power divided by input power. Power is sent at high voltage over long lines, because for a given power P the line current is I = P/V, and the loss I² R falls as the square of the voltage. Doubling the transmission voltage cuts the line loss to one quarter.

Worked examples

Each solution shows the marks every step would earn. The sanity check tests units and size of the answer.

Example 1 (easy)

A load draws 5.0 A rms from a 220 V rms supply with a power factor of 0.80. Find the average power in W.

Marks-style solution of example 1
StepMarks
P = V rms I rms cos(phi).1
P = 220 x 5.0 x 0.80.1
P = 880 W.1
Total: 3 marks3

Answer: 880 W

Fast method: V I = 1100 VA (apparent power); times 0.8 gives 880 W.

Sanity check: Units: V A = W. The true power (880 W) is less than the apparent power (1100 VA), as a power factor below 1 requires. At a power factor of 1 the load would take 1100 W.

Example 2 (easy)

An ideal transformer has 500 turns in its primary, which is connected to 220 V. The secondary voltage is 11 V. Find the number of turns in the secondary.

Marks-style solution of example 2
StepMarks
Vs/Vp = Ns/Np.1
Ns = Np Vs/Vp = 500 x 11/220.1
Ns = 25 turns.1
Total: 3 marks3

Answer: 25 turns

Fast method: The voltage falls by a factor 20 (220 to 11), so the turns fall by 20: 500/20 = 25.

Sanity check: A step-down factor of 20 should give a turns ratio of 20 : 1, and 500 : 25 is that. A transformer with Ns more than Np would be a step-up transformer.

Example 3 (medium)

A coil of 50 turns and area 0.040 m² rotates at 3000 revolutions per minute in a uniform field of 0.20 T about an axis perpendicular to the field. Starting from the position where the emf is zero, find the peak emf in V and the emf after 1/600 s in V.

Marks-style solution of example 3
StepMarks
w = 2 pi x 3000/60 = 314.16 rad/s.1
E0 = N B A w = 50 x 0.20 x 0.040 x 314.16 = 125.7 V.1
e = E0 sin(w t) with w t = 314.16/600 = 0.5236 rad = 30 degrees.2
e = 125.7 x sin 30 degrees = 62.8 V, and the peak emf is 125.7 V.1
Total: 5 marks5

Answer: peak 125.7 V; emf 62.8 V after 1/600 s

Fast method: f = 50 Hz, period 0.02 s, and 1/600 s is 1/12 of a period = 30 degrees, so e = E0/2 = 62.8 V.

Sanity check: Units: T m² rad/s = V. One twelfth of a period corresponds to 30 degrees, and sin 30 degrees = 0.5, so the emf is half the peak, 62.8 V; this agrees with the direct calculation.

Example 4 (medium)

A load takes 10 A rms from a 200 V rms supply with a power factor of 0.60. Find the average power in W and the wattless component of the current in A.

Marks-style solution of example 4
StepMarks
P = V I cos(phi) = 200 x 10 x 0.60 = 1200 W.1
sin(phi) = sqrt(1 - 0.60²) = 0.80.1
Wattless current = I sin(phi) = 10 x 0.80.1
Average power 1200 W; wattless current 8.0 A.1
Total: 4 marks4

Answer: 1200 W; 8.0 A

Fast method: A 0.6-0.8-1 triangle: the active part of the current is 6 A, the wattless part is 8 A; P = 200 x 6 = 1200 W.

Sanity check: The two components satisfy 6² + 8² = 10², so they combine to the 10 A total. Note that the wattless current (8 A) is larger than the active current (6 A), although it does no net work.

Example 5 (medium)

A transformer is 80 percent efficient. Its primary is at 2200 V, and its secondary at 220 V feeds a resistive load of 55 ohm. Find the primary current in A.

Marks-style solution of example 5
StepMarks
Secondary current Is = Vs/R = 220/55 = 4.0 A.1
Output power = Vs Is = 220 x 4.0 = 880 W.1
Input power = output/efficiency = 880/0.80 = 1100 W.1
Ip = 1100/2200 = 0.50 A.1
Total: 4 marks4

Answer: 0.50 A

Fast method: An ideal transformer would draw 4 x 220/2200 = 0.40 A; with 80 percent efficiency the primary draws 0.40/0.80 = 0.50 A.

Sanity check: The primary current (0.50 A) is higher than the ideal value (0.40 A), as it must be, because the primary must supply the losses as well. The ratio of currents is not the turns ratio when the transformer is not ideal.

Typical trap: Using the ideal current ratio Ip = Is Ns/Np (0.40 A) even though the efficiency is given. The primary has to supply the loss as well.

Example 6 (hard, multi-step)

A series circuit with R = 30 ohm, XL = 70 ohm and XC = 30 ohm is connected to a 100 V rms source. Find the rms current, the power factor, the average power, the apparent power and the wattless current.

Marks-style solution of example 6
StepMarks
Net reactance = 70 - 30 = 40 ohm, so Z = sqrt(30² + 40²) = 50 ohm.1
I rms = 100/50 = 2.0 A and the power factor cos(phi) = R/Z = 30/50 = 0.60.2
Average power P = I² R = 4 x 30 = 120 W; apparent power = V I = 200 VA.2
Wattless current = I sin(phi) = 2.0 x 0.80 = 1.6 A, so P = 120 W and I = 2.0 A.1
Total: 6 marks6

Answer: I = 2.0 A; pf = 0.60; P = 120 W; 200 VA; wattless 1.6 A

Fast method: Z = 50 (3-4-5), I = 2 A, cos phi = 0.6; P = V I cos phi = 100 x 2 x 0.6 = 120 W, which equals I² R = 120 W.

Sanity check: Two routes to the power must agree: V I cos(phi) = 120 W and I² R = 4 x 30 = 120 W. The triangle P² + Q² = S² holds too: 120² + 160² = 200², with the reactive power Q = 100 x 1.6 = 160 var.

Example 7 (hard, multi-step)

A power station sends 50 kW through a line of total resistance 10 ohm. Find the power lost in the line when it is sent at 5000 V and when it is sent at 10000 V, in W, and the fraction of the 50 kW lost in each case.

Marks-style solution of example 7
StepMarks
At 5000 V the line current is I = P/V = 50000/5000 = 10 A.1
Loss = I² R = 100 x 10 = 1000 W, which is 2 percent of 50 kW.2
At 10000 V, I = 5.0 A and the loss = 25 x 10 = 250 W, which is 0.5 percent.2
Losses are 1000 W at 5000 V and 250 W at 10000 V; doubling the voltage divides the loss by 4.1
Total: 6 marks6

Answer: 1000 W at 5000 V (2 percent); 250 W at 10000 V (0.5 percent)

Fast method: Loss = P² R/V². Doubling V divides the loss by 4: 1000/4 = 250 W.

Sanity check: Units: A² ohm = W. The losses are small fractions of the 50 kW sent, as a well-designed transmission should give, and the quarter-ratio confirms that loss varies as 1/V².

Formulas and units

Formula and unit box for AC power, generator and transformer
ResultFormulaValid whenUnits or noteWorked example
Average powerP = V rms I rms cos(phi) = I rms² Rsinusoidal steady state, rms values; I² R form for the resistance R in seriesWExample 1
Power factorcos(phi) = R/Zseries R, L, C circuit in sinusoidal steady statedimensionlessExample 6
Apparent powerS = V rms I rmsrms voltage and rms current of any ac circuitVAExample 6
Wattless currentI sin(phi) = I X/Zseries circuit with net reactance X and impedance Z, sinusoidal steady stateAExample 4
Power triangleS² = P² + Q²; Q = V I sin(phi)sinusoidal steady state, rms values; phi is the phase angleVA (W, var)none
AC generator emfe = N B A w sin(w t); E0 = N B A wcoil of N turns rotating uniformly in uniform B, axis perpendicular to B, t=0 at zero emfVExample 3
Angular speed from rpmw = 2 pi (rpm)/60rpm to rad/s, any uniform rotationrad/sExample 3
Ideal transformer voltagesVs/Vp = Ns/Npideal transformer: no flux leakage, no lossesdimensionlessExample 2
Ideal transformer currentsIp/Is = Ns/Np; Vp Ip = Vs Isideal transformer; real transformers have Ip Vp greater than Vs Isdimensionlessnone
Efficiencyeta = Vs Is/(Vp Ip)any transformer, using rms power in and outdimensionlessExample 5
Line lossI² R = P² R/V²line current I = P/V at unity power factor, line resistance RWExample 7

Use your browser's print command to print this page; the formula box prints on its own page. Download the one-page formula sheet (PDF).

Common mistakes and speed

  • Using V0 I0 cos(phi) as the average power. Why it tempts: Instantaneous amplitudes appear in v = V0 sin(w t), and the factor one half from averaging is forgotten; the doubled value is usually among the options.
  • Saying that the power in a pure inductor or capacitor is V I. Why it tempts: A current flows and a voltage is present, so V I seems the natural power, but the phase is 90 degrees, cos(phi) = 0, and the average power is zero.
  • Applying the turns ratio to the currents the wrong way round. Why it tempts: The voltage ratio Vs/Vp = Ns/Np is memorised; for currents the ratio is inverted, Ip/Is = Ns/Np, so the current follows the opposite turns ratio; applying Ns/Np to Is/Ip gives the inverted answer, which appears as an option.
  • Ignoring the efficiency of the transformer when the primary current is asked. Why it tempts: The ideal relation is simple and fast; the efficiency is a quantity that has been written in the stem, so the ideal answer is a close wrong option.
  • Taking the second loss from the original power instead of the remaining power. Why it tempts: Subtracting percentages (8 percent and 5 percent) from 100 is quick; the second loss applies to what is left after the first, so the two are not added.
  • Reading rpm as rad/s in E0 = N B A w. Why it tempts: The speed is given in revolutions per minute and the formula needs rad/s; the factor 2 pi/60 is missed and the answer is wrong by a factor of about 10.

Time per question and fast method

Target: about 100 seconds per question.

For power write P = I² R, which needs only the current and the resistance, or P = V² cos²(phi)/R at fixed V. Use a 3-4-5 triangle for Z and cos(phi). For a transformer find the secondary current first, then convert power with the efficiency, and for transmission use the loss P² R/V², which falls by 4 when V is doubled.

Recall quiz

Pick an option for each question. Your answers stay on this page and are not sent anywhere.

Question 1. A load takes 4.0 A rms at 230 V rms and power factor 0.50. What is the average power, in W?
Show the answer

Answer: B: 460 W. P = V I cos(phi) = 230 x 4.0 x 0.50 = 460 W.

Question 2. A transformer has Np = 400 and Ns = 40, and the primary current is 0.50 A (ideal). What is the secondary current, in A?
Show the answer

Answer: D: 5.0 A. Is = Ip Np/Ns = 0.50 x 400/40 = 5.0 A; the step-down transformer raises the current.

Question 3. A coil of 200 turns and area 0.010 m² rotates at 50 rad/s in a field of 0.40 T. What is the peak emf, in V?
Show the answer

Answer: C: 40 V. E0 = N B A w = 200 x 0.40 x 0.010 x 50 = 40 V.

Question 4. A line of 8.0 ohm carries 25 A. What is the power lost in it, in W?
Show the answer

Answer: A: 5000 W. Loss = I² R = 625 x 8.0 = 5000 W.

Question 5. What is the average power absorbed by an ideal inductor connected to an ac source?
Show the answer

Answer: D: Zero. The current lags the voltage by 90 degrees, so cos(phi) = 0 and the average power over a cycle is zero; the current is wattless.

Question 6. Why can a transformer not be used with a dc supply?
Show the answer

Answer: C: Dc gives no changing flux and so no induced emf in the secondary. The secondary emf comes from a changing flux, which needs a changing current in the primary.

Practice

Test your answers nowFull-length mocks

Previous-year questions

Previous-year questions are not imported yet. Previous-year questions are not imported yet; see the official papers on the NTA site. Official NTA papers page.

Going deeper and revision

Average power, apparent power and power factor

P = V rms I rms cos(phi) = I rms² R = V rms² R/Z² in a series circuit. Apparent power S = V rms I rms (volt-ampere) and reactive power Q = V rms I rms sin(phi). The three form a triangle: S² = P² + Q². Special cases: pure resistor, cos(phi) = 1; pure L or C, cos(phi) = 0; RL with R = XL, cos(phi) = 0.707 at phi = 45 degrees; resonance, cos(phi) = 1. The average power at a fixed supply voltage is largest at resonance, where P = V²/R, and for a given R it varies as cos²(phi), since P = V² cos²(phi)/R. Do not use V0 I0 for the average power without the factor 1/2.

Wattless current and energy exchange

In a pure inductor the energy is stored in the magnetic field during a quarter cycle and returned to the source in the next, so the average power over a cycle is zero and the current is called wattless. The same is true of a pure capacitor. In a series LCR circuit away from resonance the energy swings between the source and the reactive elements and the source supplies only I rms² R on average. The wattless component of the current is I rms sin(phi) and its product with V rms is the reactive power. A hot-wire or moving-iron ammeter reads the total rms current, including the wattless component, and a wattmeter reads P. The useful or active component of the current is I rms cos(phi).

AC generator: emf and the dependence on parameters

e = N B A w sin(w t), E0 = N B A w = 2 pi f N B A. The rms emf is E0/sqrt2. Doubling the speed doubles both the frequency and the amplitude; doubling the number of turns or the field doubles the amplitude only. A flux plot is a cosine and the emf is the negative of its slope, 90 degrees out of phase. In a practical generator the coil (armature) is turned by water, steam or wind, and slip rings carry the emf to the outside circuit; the same machine with the roles reversed is an ac motor. Examiners give rpm, which must be converted to rad/s with w = 2 pi (rpm)/60, and ask for the peak, rms or the instantaneous value at a given time.

Transformer relations and efficiency

Ideal: Vs/Vp = Ns/Np and Ip/Is = Ns/Np. For a transformer with efficiency eta, eta = Vs Is/(Vp Ip), so Ip = Vs Is/(eta Vp). The load resistance R seen by the secondary determines Is = Vs/R, and from the primary side the effective resistance is R (Np/Ns)². Transformer rating is in volt-ampere, because the heating in the windings depends on the current. A transformer cannot raise power; a step-up transformer raises voltage at the cost of current. Energy losses: copper loss (I² R of windings), iron loss (eddy and hysteresis), and flux leakage. Remedies: thick wire, laminated core, soft-iron core, coil winding in layers. An autotransformer uses one coil. Power transmitted P = V I, line loss I² R = P² R/V².

What examiners test and the usual traps

Typical items: average power and power factor for a given series circuit; power at resonance compared with power elsewhere; wattless current from a power factor; peak and rms emf of a rotating coil with the rpm conversion; the transformer current ratio (inverted, a common error); efficiency and input current; transmission loss at different voltages; and statements such as a transformer works on dc (false) or a pure inductor consumes power (false). Traps: using V0 I0 cos(phi) for the average, applying the voltage ratio to the currents, taking the percentage loss from the wrong base when a loss is followed by an efficiency, confusing the apparent power with the true power, and reading the rpm as rad/s.

Memory hook

Suppose the electricity board brings power to a village through a long thin wire from a distant power plant. The same wire feeds a bulb in a house and a motor in the flour mill, and the wire gets warm when the mill runs.

  1. To deliver the same power, a wire at a higher voltage carries a smaller current, and the wire heats according to the current squared, so sending power at a very high voltage keeps the wire cool.
  2. A transformer near the plant raises the voltage for the long run and another near the village lowers it again for homes. Nothing is gained in power; the voltage goes up only as the current goes down.
  3. The flour mill's motor draws extra current that does no useful work. That wattless current still warms the wire, which is why the electricity board prefers a power factor near 1.

Transformers trade voltage against current in the ratio of turns, power is V I cos(phi), and line loss is I² R, so a high voltage and a good power factor both save energy.

Raise the voltage, lower the current, and the wire stays cool: power is V I cos(phi), loss is I² R.

Revision card

Try to answer each without looking above.

  1. Write the average power in an ac circuit and the power factor of a series circuit.
  2. Explain why the average power in a pure inductor or capacitor is zero.
  3. Define wattless current and give its value in terms of I and phi.
  4. Derive the peak emf of an ac generator and say when the emf is zero and when it is a maximum.
  5. State the voltage and current relations of an ideal transformer and its efficiency formula.
  6. Name four causes of energy loss in a transformer and the remedy for each.

Sources and review

Reviewed Reviewed on 2026-11-20: every number recomputed by code and independently reviewed; textbook section references pending.

  • Method: Every number in worked examples, recall checks and notes recomputed by code; claims recomputed independently by a separate verifier run using other numerical methods; textbook section references not yet attached; wording defects found were fixed afterwards and re-linted (code checks re-run) but not re-reviewed by a second run; syllabus scope compared with the NTA JEE Main 2026 syllabus text (by the verifier; see the report)
  • Reviewer: independent verifier agent run (not the author)
  • Date: 2026-11-20
  • Defects found: 2; fixed: 2
  • Report: content/reviews/learn5-emi-2026-11-20.md

Textbook references

  • NCERT Physics Part 1, Class 12 (reprint 2026-27), Chapter 7: Alternating Current, Example 7.7 POWER IN AC CIRCUIT: THE POWER FACTOR (read 2026-11-22)
  • NCERT Physics Part 1, Class 12 (reprint 2026-27), Chapter 6: Electromagnetic Induction, 6.8 AC GENERATOR (read 2026-11-22)
  • NCERT Physics Part 1, Class 12 (reprint 2026-27), Chapter 7: Alternating Current, Summary SUMMARY (read 2026-11-22)
  • NCERT Physics Part 1, Class 12 (reprint 2026-27), Chapter 7: Alternating Current, 7.8 TRANSFORMERS (read 2026-11-22)
  • NCERT Physics Part 1, Class 12 (reprint 2026-27), Chapter 7: Alternating Current, 7.7 POWER IN AC CIRCUIT: THE POWER FACTOR (read 2026-11-22)
  • NCERT Physics Part 1, Class 12 (reprint 2026-27), Chapter 7: Alternating Current, Points to Ponder POINTS TO PONDER (read 2026-11-22)

Sources used

  • Syllabus: NTA JEE (Main) 2026 syllabus, Physics, Unit 14 (https://jeemain.nta.nic.in/document/syllabus-2026/), imported into syllabus/lines/jee-main/2026.json
  • Standard school-level ac power, generator and transformer results; no textbook section reference attached yet (to be sourced at verification). Content written fresh for this site.

How labels work: see how answers and lessons are verified. Found a mistake? Use Report an error on any question page.