EngineeringRise

A generating station feeds 100 kW into a transmission line at 5000 V. The two wires of the line have a total resistance of 20 ohm. At the far end a step-down transformer of efficiency 95 percent supplies the consumers. The power delivered to the consumers, in kW, is

Answer: (C) 87.4 kW Status: Verified (T1). Checked by code and independent solves on 2026-11-20.

  1. 92.0 kW
  2. 87.0 kW
  3. 87.4 kW
  4. 80.0 kW

Solution

  1. Line current I = P/V = 100000/5000 = 20 A.
  2. Line loss = I² R = 400 x 20 = 8000 W = 8 kW, so 92 kW reaches the transformer.
  3. Output = 0.95 x 92 = 87.4 kW.

Fast method

Loss is 8 percent in the line; 5 percent of the remaining 92 kW, not of 100 kW, is lost in the transformer. Subtracting 8 and 5 from 100 gives the tempting 87.0 kW.

Expected time: about 150 seconds. Difficulty: hard.

Topic page: AC power, generator and transformer

Test your answers now