EngineeringRise

An ideal reversible refrigerator keeps its inside at -3 degrees C while the room is at 27 degrees C. For 2.0 kJ of work supplied in a certain time, the heat removed from the inside, in kJ, is

Answer: (C) 18 kJ Status: Verified (T1). Checked by code and independent solves on 2026-11-20.

  1. 20 kJ
  2. 22 kJ
  3. 18 kJ
  4. 16 kJ

Solution

  1. T_cold = 270 K and T_hot = 300 K. For a reversible refrigerator the coefficient of performance is COP = T_cold/(T_hot - T_cold) = 270/30 = 9.
  2. Heat removed from the cold space Q2 = COP x W = 9 x 2.0 = 18 kJ.
  3. Heat rejected to the room is Q2 + W = 20 kJ, which is the tempting second option.

Fast method

Temperatures are 270 K and 300 K, so COP = 9 at once. Q2 = 9 W = 18 kJ. The question asks for heat removed from the inside, not the heat dumped into the room (20 kJ).

Expected time: about 90 seconds. Difficulty: medium.

Topic page: Second law, reversible and irreversible processes

Test your answers now

Report an error

Think the question, answer or a step is wrong? One tap tells us. We check it and publish the correction.